Safety and Protection Devices安全及;ぷ爸
冻干机装有以下安全及;ぷ爸,以确保设备在法式中的靠得住性:
若是断电:
? 箱体和冷阱之间的主阀地位没有变动
? 所有其它的阀门都关关以维持设备内部的齐全性,真空泵抽气管上装的安全阀关关以预防真空泄漏
? PLC 的电池能够维持贮存的信息,PLC 法式也贮存在EEPROM 中
? 来电后,法式将从断电时的法式点沉新起头其它安全装置:
? 每个压缩机上装有一个压力开关,能够在排出口压力过高时,自动断开压缩机
? 在造冷管路中由于温度升高(重要是设备;保┗嵩斐傻脱共嗟难沽ι,每台压缩机上都有一个低压开关来预防压力升高,压缩机自动起动并向高压侧回收造冷剂。
? 若是在升华阶段,箱体真空上升到借鉴点以上,搁板加热将会自动堵截,若是真空持续上升,搁板将起头冷却
? 当过温时,2 个安全温度调节器会堵截硅油加热器
? 若是压差降落,备份泵启动,一个压差开关监督器会监测循环泵(仅合用于双泵系统)
? 当缺油或者油泵不工作时,每台压缩机上的油压差开关会堵截压缩机
? 所有的电机上都装有D立的过载堵截开关
? 软件中的内部自锁法式可预防误操作,如当箱体和冷阱在真空状态下打开排水阀和化霜入口阀
The freeze dryer is equipped with the following safety and protection devices to ensure total process reliability:
In the event of power failure:
?The position of the main valve between the chamber and the ice condenser remains unchanged
?All other valves are closed to maintain the plant integrity. The valves in the inlet to the vacuum group are automatically closed to prevent leakage through the pumps.
?The PLC has battery backup, to ensure information is retained. The PLC program is also stored in non-volatile EEPROM memory.
?When power is re-established, the cycle is resumed from the same point where the power failure occurred
Other safety features:
?A high pressure switch on each refrigeration compressor stops the compressor in the event of high discharge pressures.
?On each compressor, a low pressure switch prevents a pressure increase in the low-pressure side of the refrigeration circuit due to any temperature increase (typically when the plant stops). The compressor automatically starts and transfers the refrigerant to its high-pressure side.
?If the chamber vacuum rises above a programmed alarm point during the sublimation sequence, shelf heating is automatically switched off. If the vacuum continues to rise thereafter, shelf cooling is initiated.
?Two safety thermostats switch off the silicone oil heater should an over-temperature condition arise.
?A differential pressure switch monitors the performance of the duty circulation pump. If the differential pressure falls the standby pump is started (only applicable for machines with two circulation pumps).
?Differential oil pressure switches on each refrigeration compressor switch off the compressor in case of lack of oil or failure of the oil pump.
?All motors are fitted with individual over current breakers.
?Software interlocks prevent miss-operation of the equipment e.g. opening drain or defrost inlet valves when the chamber and condenser are under vacuum etc.
ALARM LIST报警列表 | |
Process Alarms 工艺报警 | Component Alarms部件报警 |
Poor Vacuum – Two alarms 真空不及 – 两个报警 | High Refrigerant Pressure 造冷剂压力高 |
High Shelf Temperature 搁板温度高 | Low Compressor Oil Pressure 压缩机油压低 |
Low Shelf Temperature 搁板温度低 | Low Compressed Air Pressure 压缩空气压力低 |
Low vacuum 低真空 | High Silicone Oil Temperature 硅油温度高 |
Low Silicone Oil Pressure 硅油压力低 | |
Low Cooling Water Pressure 冷却水压力低 | |
Other depending on mc. Specification 基于指标的其它报警 | |
Note 注: The operator is notified audibly of alarms by a horn and visually by a lamp, computer screen displays. 操作者将通过声光报警及屏幕显示得到报警通知。 | |

402cc永利集团重要产品:冷水机冷冻水机,冷却水循环机,冰水机,超低温冰箱,冻干机冷冻干燥机,低温槽,恒温槽,造冰机,层析冷柜,冷藏柜,气溶胶喷雾器,法式冷冻装置,冷冻仪,染色体分析系统。